Substation Automation

  • Home
  • Products
  • Power Energy
  • Substation Automation

Products

  • Data Acquisition
    • W-M1B Series
      • RS-485 Analog Module
      • RS-485 Digital & Relay Module
    • W-M2B & W-M2J Series
      • W-M2B -Modbus RTU
        • Analog Module
        • Digital & Analog Module
        • Digital & Relay Module
      • W-M2J -Modbus TCP
        • Analog Module
        • Digital & Analog Module
        • Digital & Relay Module
  • Power Energy
    • Telecontrol
    • Substation Automation
    • Communication
    • Power Meter
  • Industrial Communication
    • Gateway
    • Converter
  • Software
    • Elipse
  • 【net-line BCU-50】 Modular bay station controller 1
  • 【net-line BCU-50】 Modular bay station controller 2
  • 【net-line BCU-50】 Modular bay station controller 3
  • 【net-line BCU-50】 Modular bay station controller 4
  • 【net-line BCU-50】 Modular bay station controller 5
  • 【net-line BCU-50】 Modular bay station controller 6
  • 【net-line BCU-50】 Modular bay station controller 7
  • 【net-line BCU-50】 Modular bay station controller 8
  • 【net-line BCU-50】 Modular bay station controller 9
  • 【net-line BCU-50】 Modular bay station controller 10

【net-line BCU-50】 Modular bay station controller

Production information
 

net-line BCU-50 | Modular Bay Station Controller

Input/Output Cards in 14 Slots
Cascadable up to 16 module frames.
Up to 6 separate Ethernet network segments with VPN tunnel 
 DNP3, SYM² meter connection
4 serial interfaces with IEC 60870-5-10x protocol
224 digital I/O*, 112 analogue I/O*
Order
Datasheet

BCU-50 -  Robustness across the board

Bay station controllers in the electrical power supply must withstand special environmental requirements, especially when the station automation is used in high-voltage equipment, strongly vibrating or shock generating system components as well as environments with a seismic risk.



➨BCU-50 ➨BCU-50-W ➨BCU-50-SC in preparation ➨Cable clamping tray BCU-50
14 slots
224 digital I/O*, 112analogue I/O*
6 LAN segments*
as BCU-50 with wall-mounting
(T = 165 mm)
BCU-50 with reverse mounting 19"
frame, terminals at the back, local
operator terminal via 10" monitor
Cable strain relief (H + 37 mm)
 
  • Fields of use 
  • Station and bay controller in medium and high-voltage switchgears
  • Gateway and communication router between station buses, field bus and control systems
  • Monitoring and control unit for the utilities, waste management and manufacturing industry

Same as at its brother FW-50, a particular strength of BCU-50 lies in the implementation of communication tasks with substations and control systems of many different manufacturers.

Specifications
  • Technical data:  net-line BCU-50
Design Modular bay station controller for substation automation, cascadable
BCU-50-M: V2a/aluminium rack with  7 slots
BCU-50-L:   V2a/aluminium rack with 14 slots
Configuration Example: Max. input/output expansion
14 I/O slots (up to 224 dedicated I/O), 2 Ethernet 10/100BaseTx auto-MDIX
Example: max. communication
6 switches integrated of 4 RJ-45 10/100 MBit/s or FO ST/SC 100 Mbit/s + RJ45
4 serial interfaces, 8 E/A slots (up to 128 dedicated I/O) 
28 FO-links serial as starcoupler e.g. to protection devices
Inputs/outputs Selection of 50 plug-in cards for: Single-/double-point, transformer step indications,
measurands and integrated totals, single/double commands (1.5/2-pole),
command termination, 1 of n monitoring, set-point values, integrated total outputs
Protocols IEC 61850 · IED and protective device coupling
IEC 60870-5-101 · telecontrol technology, station control technology
IEC 60870-5-103 · protective device coupling
IEC 60870-5-104 · TCP/IP coupling to control center
DNP3 server · serial /TCP
IEC 62056-21 · meter connection (IEC 1107)
SML · SyM² meter connection via Ethernet
DSfG · Digital interface for gas measuring devices
Modbus RTU/TCP · master/slave, fieldbus MPI/3964R/RK512
SNMP · network management, NTP/SNTP/DCF clock synchronization
VPN tunnel · IPsec [IKEv1/IKEv2] , OpenVPN from  setIT V5.5
PLC programming IEC 61131-3 compatible via codeIT, 128 kb program memory
CPU-5E series5e RISC-Processor Cortex-A8, 1200MIPS@800 MHz, FPU, Watchdog, real-time clock 
 1 GB memory (512 MB SDRAM, 512 MB SLC Flash)
Memory expansion SDHC card up to 8 GB optional, 1 GB up to setIT V5.4
Real-time clock summer/winter time changeover, leap year correction,  max. error ±20 ppm 
 over entire Temperature range with maintenance-free buffer 60 days,
Status displays CPU: 12 LEDs in the front panel, green, red
I/O cards: Card error, status LED to process data (binary)
interfaces: Send and momentary contact signals depending on card type
Operational controls PLC switch in front panel RUN/STOP
USB pushbutton for config./backup/recovery function
Programming interface Ethernet LAN 10/100BaseTx, auto-MDIX,
USB device, USB 2.0 host 12 MBit/s (configuration/archive via memory stick)
Supply voltage 24 / 48 / 60 / 110 / 220 V DC, max. 40 W 
Power-Fail management, failure bypass min. 50 ms,
monitoring of supply voltage (lockout below 85%) and overload
redundant supply with separate feed optional
Electrical Safety Protection class I, clearance/creepage dist. acc. EN 60255-27, overvoltage cat.III
5 kV surge voltage 3.5 kV DC test voltage acc. to Class VW3 EN 60870-2-1
Standards EMC immunity: IEC 61850-3 (H/h), EN 60255-26,
EN 61000-4-2, /-3, /-4, /-5, /-6, /-8, /-9, /-16, /-17, /-18, /-29
EMC transient emissions: IEC 61850-3, EN 55022 /CISPR22 device class A
Vibration: EN 60870-2-2, EN 60255-21-1, IEC 60068-2-6 1 g
Shock: EN 60870-2-2, EN 60255-21-2, IEC 60068-2-27 15 g 11 ms /2-29 10g 6 ms
Earthquake: EN 60870-2-2, EN 60255-21-3 3.5 mm 1 g
Environment: IEC 61850-3,IEC 60068-2-1,/-2,/-30,/-78,EN 60721-3-3 class 3C1 3S1
Housing BCU-50 rack, metal, IP30,
BCU-50-M: DIN-rail, wall-mount, dimensions 280 x 193 x 135 mm (WxHxD) 
BCU-50-L: 19“ rack, wall mount, dimensions 483 x 193 x 135 mm (WxHxD)
Terminals MSTB screw-type terminal or Combicon spring-type terminal, 0.2...2.5 mm2 
Environment −20° ...+70°C, +55 °C recommended 
 relative humidity < 95% without condensation
 
Ordering Information
Telecontrol
FW-5 micro telecontrol station (Digital Input, Bluetooth, Relay, Analog)
FW-5-Gate micro telecontrol station (Ethernet LAN TCP/IP, RS-485, RS-232)
FW-5-Gate-4G RTU with 4G mobile radio modem (Ethernet LAN TCP/IP, RS-485, RS-232)
FW-50 scalable RTU (4/7/14 slots, up to 224 digital I/O, 112 Analog I/O)
Substation Automation
BCU-50 Modular bay station controller (14 slots, up to 224 digital I/O*, 112 analog I/O* 6 LAN segments*)
Communication
Remote I/O Flexible bus extension, an FW-5 /FW-5-GATE Remote extension modules (EWB) of the FW-5 series
PM-1 Power measurement terminal for telecontrol and substation automation 
in micro-housing, polyamide V0, IP20, DIN top-hat rail installation