Advanio Technology Co., Ltd.
  • Products
  • Downloads
  • Latest News
  • About Us
  • Contact Us

Telecontrol

  • Home
  • Products
  • Power Energy
  • Telecontrol

Products

  • Data Acquisition
    • W-M1B Series
      • RS-485 Analog Module
      • RS-485 Digital & Relay Module
    • W-M2B & W-M2J Series
      • W-M2B -Modbus RTU
        • Analog Module
        • Digital & Analog Module
        • Digital & Relay Module
      • W-M2J -Modbus TCP
        • Analog Module
        • Digital & Analog Module
        • Digital & Relay Module
  • Power Energy
    • Telecontrol
    • Substation Automation
    • Communication
    • Power Meter
  • Industrial Communication
    • Gateway
    • Converter
  • Software
    • Elipse
  • 【net-line FW-5-GATE】 Micro Telecontrol Station 1
  • 【net-line FW-5-GATE】 Micro Telecontrol Station 2
  • 【net-line FW-5-GATE】 Micro Telecontrol Station 3
  • 【net-line FW-5-GATE】 Micro Telecontrol Station 4
  • 【net-line FW-5-GATE】 Micro Telecontrol Station 5

【net-line FW-5-GATE】 Micro Telecontrol Station

Production information
 

net-line FW-5-Gate | Micro Telecontrol Station

2 Ethernet LAN TCP / IP connections
2 RS-485 field interfaces
CL/S0 meter interface in FW-5-GATE-cl
RS-232/V.24 interface
Temperature sensor, -20° to 100° C
Integrated wide range power supply unit, 20 to 72 V DC
or 230 V AC power supply in FW-5-GATE-230
Order
Datasheet

FW-5-Gate -  Compact and smart!

More communication possibilities even in smaller spaces, integrated inputs/outputs have been omitted. The FW-5-GATE can also be supplemented with expansion modules and interface modules. Cost-effective solutions for intelligent secondary distribution networks and smart metering through further interfaces with SML/SyM² meter integration, among others. An integrated temperature sensor measures the station temperature, which can be used e.g. for overload checks on a transformer.

  • Deployment as Transparent Protocol Converter
From setIT V5.3.7 respectively V5.4. (for CL versions ) the FW-5-GATE can also be operated in the "Protocol converter" mode. In this case, the device enables the conversion of the following protocols, without that any process data needs to be configured:
  • IEC -101 to IEC -104
  • IEC -101 to IEC -104 (VPN encrypted)
  • IEC -104 to IEC -104 (VPN encrypted)
  • IEC -104 to IEC -101

The connection can be established parallel to several control centers.

  • Fields of use 
  • Intelligent secondary unit substation with integration of earth fault/short circuit indicators, network analysis systems and protective devices
  • Smart meter integration in energy management systems and remote meter reading control centers
  • Intelligent measurement point for wide range of regulation in distribution networks
  • Field devise in transformer substations with protection device coupling
  • Monitoring of media and infrastructure systems in pipelines

Specifications
  • Technical data:  net-line FW-5-Gate
Construction Substation/bay control, telecontrol and automation system in plastic housing, expandable with
I/O and communication modules for DIN rail mounting
Communication 2 Ethernet LAN TCP/IP, 10/100BaseTx, auto-MDIX, auto-negotiation
1 EIA/RS-485 interface, galvanically isolated
1 EIA/RS-485 meter interface or CS/S0 interface, galvanically isolated 
1 EIA/RS-232/V.24 interface
Inputs/outputs Sensor for ambient/transformer temperature,  -20° to 100° C ±2° C,up to 12 expansion modules
for operation of single-/double-point, transformer tap and alarm signals, measurands, metered
values, single, double and transformer tap commands, set points, metered value pulse outputs
Input/output single-point, double-point, transformer tap position and alarm signals, measurands, metered
values, single, double and transformer tap commands, set points, metered value pulse outputs
, expandable up to 12 I/O modules
Protocols IEC 61850 · IED and protective equipment 
IEC 60870-5-101 · telecontrol technology, station control technology 
IEC 60870-5-103 · protective equipment 
IEC 60870-5-104 · TCP/IP link to control centre 
IEC 62056-21 · smart meter link (former IEC 1107) 
SML · SyM² smart meter link via Ethernet 
DNP3 · server serial/IP
DSfG · natural gas interface
Modbus RTU/TCP · master/slave 
Profibus-DP slave, MPI/3964R/RK512 · field bus 
SNMP · network management 
NTP/SNTP/DCF · clock synchronisation 
VPN-Tunnel · IPsec IKEv1/IKEv2, OpenVPN
PLC programming IEC 61131-3 compatible via codeIT, 128 kb program memory
CPU-5E series5e RISC processor Cortex-A8, 1200 MIPS@800MHz, FPU, watchdog, real-time clock 
1GB memory (512 MB SDRAM, 512 MB SLC Flash)
Memory expansion optional SD card up to 8 GB, 1 GB up to setIT V5
Real-time clock Errors max. ±20 ppm over entire temperature range, maintenance-free buffer, daylight saving
time changeover, leap year correction
Status displays LED in front panel for system, communication and binary process values 
detailed diagnostics via integrated web server
Operational controls PLC switch in front panel RUN/RUN-P/STOP 
USB pushbutton for configuration/backup/recovery functions
Programming interface Ethernet LAN 10/100BaseTx, auto-MDIX, USB 2.0 device 12 Mbit/s, 
USB 2.0 host 12 Mbit/s (configuration/archive synchronisation via stick)
Fault signal output to be configured to relay output, parameterisable sys-LED
Power supply +20 to 72 V DC max. 5 W, (24 V DC 0.2 A/60 V DC 0.1 A) without expansion 
 Power failure management with power failure buffering
24 V DCvia expansion module PS-60
Dielectric strength 5 kV surge supply & process I/O to PE, according to class VW3 
2.5 kV surge, supply to measurands, EIA/RS-232, USB
Standards EMC: IEC 60870-2-1, EN 61000-4-x, EN 55022, 
Insulation: IEC 60870-2-1, IEC 60255-5 
NSRL: DIN EN 60950
Housing Micro, polyamide V0, IP20, weight: 240 g, FW-5-GATE-230 300 g 
dimensions W×H×D: 45×105×115 mm; FW-5-GATE-230 68×105×115 mm
expansion: 22.5×105×115 mm
Installation DIN rail mounting, DIN-EN 60715 TH35
Terminals MSTB removable screw-type or spring terminal, 0.2 bis 2.5 mm2
Ambience −20° to +70°C, from 24 V DC: +60 °C, in the value range from 48 V DC: +60 °C,
from 5 EUs: +60 °C  Relative humidity < 95%, without condensation
 
Ordering Information
Telecontrol
FW-5 micro telecontrol station (Digital Input, Bluetooth, Relay, Analog)
FW-5-Gate micro telecontrol station (Ethernet LAN TCP/IP, RS-485, RS-232)
FW-5-Gate-4G RTU with 4G mobile radio modem (Ethernet LAN TCP/IP, RS-485, RS-232)
FW-50 scalable RTU (4/7/14 slots, up to 224 digital I/O, 112 Analog I/O)
Substation Automation
BCU-50 Modular bay station controller (14 slots, up to 224 digital I/O*, 112 analog I/O* 6 LAN segments*)
Communication
Remote I/O Flexible bus extension, an FW-5 /FW-5-GATE Remote extension modules (EWB) of the FW-5 series
PM-1 Power measurement terminal for telecontrol and substation automation 
in micro-housing, polyamide V0, IP20, DIN top-hat rail installation